Your Position: Home > News > Company News

LED lighting energy-saving product certification process and the five common problems

2015/11/4      view:
LED road/tunnel lighting products, LED tube light, reflective since ballast LED lights, and other three kinds of LED lighting energy-saving product certification to carry out the time is not long, because the three categories of certification business, have much difference with the traditional lighting product certification enterprises encounter many problems in the certification process. In order to help enterprises to complete certification, contributing please relevant experts, enterprises often appear in the certification process to solve the problem, including the authentication model, obtaining the necessary for energy conservation, energy conservation in the cell division principle, testing cycle, factory inspection content, etc.



1, what is LED lighting energy-saving product certification process?



A: LED lighting energy-saving product certification process and the traditional light source lighting products certification process

Similar.



Need to pay attention to the problem, one is the sample testing is a necessary part in energy saving certification, after sample inspection, enterprise through the factory inspection, even the same kind of product only needs a factory inspection. 2 it is certification shall apply to the headquarters of the CQC, fill out the application on CQC web site, www.cqc.com.cn, product inspection and factory inspection tasks arranged by CQC headquarters, shall be borne by the testing agency and CQC sub-center respectively, enterprise problems encountered in the process of certification need to communicate with relevant departments, but can be by CQC headquarters coordination.



2, access to energy saving certification to obtain safety certification?



A: LED lighting products meet safety requirements is the necessary condition to get energy saving certification, rules of certification of energy-saving LED lighting products must first obtain safety certification. Security authentication and certification of energy conservation should be submitted separately, all kinds of energy-saving product certification and safety certification application class as shown in table 1, according to the technical standards and certification rules as shown in table 2 and table 3.





It is important to note that the energy saving certification requirements apply for alone with the safety of the product safety certification requirements are different. Products such as LED road/tunnel lighting, if apply for energy-saving certification, when doing the safety certification, need to examine the quality of the product, suitable environmental temperature. In these products, do security certification is not required.



Energy-saving certification in order to maintain the consistency of the security requirements of advice to never do safety certification of products, the safety the requirements of part reference energy-saving certification requirements of technical specification; To have received CQC safety certification of the product, when applying for energy-saving certification, an application regarding the change shall be submitted at the same time the security project, added the corresponding difference experiment was carried out.



3, the principle of division of energy-saving certification and safety certification units respectively is what?



Answer: safety certification units classification principles mainly considering factors affecting the safety of products, such as the control device of the circuit principle. Energy-saving attestation mainly consider the factors affecting the performance of the product, such as optical system. LED lighting products, the classification principles of safety and energy efficiency certification unit are shown in table 4.



For units classification problems need attention, it is energy saving certification in general is fine than units classification principles of safety certification, the same kind of product when doing energy-saving certification is divided into different units, but doing safety certification may be for the same unit. Because accept the engineer at the time of application, can't get all the information of the product, can only fill in the application of information according to the enterprise to carry on the preliminary judgment, therefore in order to avoid caused by cell division is not correct again and again to apply for, it is recommended to fill out the application, with each model of the technical parameters, such as for reflective since ballast LED lamp with luminous flux, the beam Angle, light intensity in the center, power, power factor, correlated color temperature, voltage, frequency, LED canister light indicate the luminous flux, the correlated color temperature, power, power factor, size, voltage, frequency, accepted by the engineer according to these information can make general judgment, once there was a problem timely feedback to the applicant.



4, energy saving certification inspection period how long?



A: the whole life cycle of 10000 h, product inspection in three phases, the first phase of 3000 h, the second phase of 3000 h, the third stage is 4000 h.



5, LED energy-saving product certification, what is the content of the factory inspection?



Answer: factory inspection is an important part of product certification, the product can be arranged after the inspection, the contents of the inspection for the product consistency check and the factory quality assurance ability. The products consistency check to verify the contents of have the following several aspects. Is a product certification logos should be consistent with the indicated the information of product inspection report. Second, the structure of certified products should be consistent with the product inspection report and the product description. Three are key raw materials used in the certification of the product components should be consistent with the product inspection report and product description.